Updated Successfully.
Update Contact
Contact Information
Description Information
Jobs

Job Name Stage Amount
Open Activities

Open Tasks 0
Open Meetings 0
Open Calls 0

Closed Activities

Closed Tasks 7
Closed Meetings 0
Closed Calls 18

24 hour Follow up on 31-33 Atchison Street, Wollongong Aug 08, 2019
Michael Eskaros
Closed Time: 2019-08-27T08:43:27+05:30
Status: Completed



24 hour Follow up on 35 Kenny Street, Wollongong Aug 14, 2019
Michael Eskaros
Closed Time: 2019-08-27T08:43:23+05:30
Status: Completed



Best and Final Mar 27, 2020
Yousif Yousif
Closed Time: 2020-03-25T19:15:55+05:30
Status: Completed
Estimating Task Type: Final Reprice - Priority 1
Description: Discuss pricing with RM prior submission.

FSS9632 - Urban May 15, 2020
Yousif Yousif
Closed Time: 2020-07-31T10:17:14+05:30
Status: Completed
Estimating Task Type: Final Reprice - Priority 1


FSS9632 - URBAN Jul 21, 2020
Yousif Yousif
Closed Time: 2020-07-31T09:44:23+05:30
Status: Completed
Estimating Task Type: Final Reprice - Priority 1


Potential Variation Check Feb 12, 2021
Yousif Yousif
Closed Time: 2021-02-12T07:07:24+05:30
Status: Completed
Estimating Task Type: Variation - Priority 2
Description: Karl informs me that we need to install 28 beams over a void at Kenny street Wollongong blaq, as these is no slab to build off for 12 story’s. We first need to check: 1) Was this allowed for in our scope, quotation (and Sub-contractor contract).? 2) Is it a variation we should charge for? 3) If it is a variation, can you please price it up for me. Will need transportation and hire and install for this job please. We need a pice and approved please Kemal, 1) no it was not allowed. 2) This is a contractual decision but I will elaborate about the cause of this variation: -We original allowed for the scaffold to be based of the GF through the voids. -The engineer designed the scaffold in the voids with a different configuration to the scaffold that was meant to be built on top of it, hence, scaffold could not be topped up the void scaffold. -Also, the voids have not been built yet because the void space is occupied with form-work, hence, needles were required. 3- The variation to Subbie will be 54h for erection and dismantle of needles = $2,700.00+GST (internal variation). 4-If we are to charge the builder, the variation should be = $6500.00+GST Yousif

fss9632-35 Kenny Street, Wollongong Mar 12, 2021
Yousif Yousif
Closed Time: 2021-03-12T07:35:41+05:30
Status: Completed
Estimating Task Type: Variation - Priority 2
Description: Hi Yousif, this is email sent by Karl below. any queries, please ring him to clarify. .As per mark up we need to build a extra bay off our perimeter scaffold this will need double legs in and out and also access to the scaffold deck this is not in our contract , we are already up to level 7 so this will need to modifying by removing mesh removing double legs, manual handle gear up and also the dismantling from level 12 Kemal Kemal, Please pay the subbie $1864 + GST (Erection and dismantle) and Charge the builder $3,780.00+GST Yousif

Follow Up - Final Negotiation
Jul 22, 2020 03:30 AM
Michael Eskaros
Contact Name:

Status: Cancelled
Descriptions:

Update
May 21, 2020 05:55 AM
Michael Eskaros
Contact Name:

Status: Completed
Descriptions: Updated quote sent.

Follow Up
Apr 29, 2020 03:30 AM
Michael Eskaros
Contact Name:

Status: Cancelled
Descriptions:

Update
Apr 22, 2020 06:54 AM
Michael Eskaros
Contact Name:

Status: Completed
Descriptions: RM talking to Mark Elias.

Update
Mar 30, 2020 06:45 AM
Michael Eskaros
Contact Name:

Status: Completed
Descriptions: Reprice submitted saturday.

Follow Up
Mar 16, 2020 08:41 AM
Michael Eskaros
Contact Name:

Status: Completed
Descriptions: Once the new plans have been finalzied hopefully by friday. he will send it back out for tender.

Follow Up
Feb 17, 2020 10:27 AM
Michael Eskaros
Contact Name:

Status: Completed
Descriptions: Still on hold. problems with council. still completing design. should be a month or so away.

Follow Up
Nov 26, 2019 04:54 AM
Michael Eskaros
Contact Name:

Status: Completed
Descriptions: The job is on hold. Won't start till Feb. Having issues with Level 1 and council.

Follow Up
Oct 11, 2019 02:30 AM
Michael Eskaros
Contact Name:

Status: Cancelled
Descriptions:

Up
Oct 04, 2019 06:41 AM
Michael Eskaros
Contact Name:

Status: Completed
Descriptions: RM Advised that it wasnt ready to be assessed.

Update
Oct 04, 2019 06:39 AM
Michael Eskaros
Contact Name:

Status: Completed
Descriptions: RM Advised that it wasnt ready to be assessed.

Follow Up
Sep 16, 2019 08:48 AM
Michael Eskaros
Contact Name:

Status: Completed
Descriptions: Looking very favourable for us. We're priced in line with everyone else. Wants a hoist added and it should be ready for approval by Mark when he gets back.

Follow Up
Sep 13, 2019 06:22 AM
Michael Eskaros
Contact Name:

Status: Completed
Descriptions: Mark is in america and will be back week after next. Said call on the 25th/26th to get feedback.

Follow Up
Sep 13, 2019 06:21 AM
Michael Eskaros
Contact Name:

Status: Completed
Descriptions: Mark is in america and will be back week after next. Said call on the 25th/26th to get feedback.

Left a Message
Sep 13, 2019 05:56 AM
Michael Eskaros
Contact Name:

Status: Completed
Descriptions:

Left a Message
Sep 13, 2019 05:55 AM
Michael Eskaros
Contact Name:

Status: Completed
Descriptions:

Follow Up
Sep 02, 2019 07:19 AM
Michael Eskaros
Contact Name:

Status: Completed
Descriptions: Resent Kenny. Will review and get back to us.

Follow Up
Sep 02, 2019 07:18 AM
Michael Eskaros
Contact Name:

Status: Completed
Descriptions: Resent kenny st. he couldnt find it. will review and get back.

Quotes

Action Job Name Subject Quote ref number Quote stage Quote Owner Cteated Time Grand Total GP%

Campaigns